RWM
SERIES
the
concept
While
we do not recommend the practice of supplying raw or filtered water
to multiple "consumers" from a single inlet source (i.e.,:
toilets, washdown pumps, air conditioners, generators, etc), we do
recognize that it is common practice to do so, particularly when
one or more of the consumers is an intermittent consumer.
If
this is your intention, protect your equipment by installing a GROCO
RWM Raw Water Manifold. You will be guided to use proper pipe or
hose sizes, thus reducing the possibility of imposing dangerous restructions
to one or all of the consumers.
The
barbed outlet is connected to the primary consumer (your main engine,
for example), and is smaller than the threaded inlet which screws
into a seacock or strainer outlet of the next larger pipe size (see
sample installations). The larger threaded end requires that a larger
strainer or inlet seacock be used, thus assuring adequate flow to
all consumers.
The
combined cross-sections of the primary consumer plus the threaded
secondary consumer connections (to A/C and generator, for example)
does not exceed the cross-section of the threaded inlet end.
sample installation filtered water
sample installation raw (unfiltered) water